Board-X Ups Online 10kva 9000W External Batteries 16x 12v up to 150AH 192VDC
-Power: 9000W
-Output: Input and output are single phase
-Frequency: 50/60HZ
-Voltage: 220V
-Battery: 16X 12V Up To 150Ah 192Vdc
-Standard communication Interface: RS232, USB, and relay output contacts or SNMP card
Dealers can View Prices. Click here
|
MODEL
|
MP RT 6k | MP RT 10k | |||
| Capacity | 6000VA/ 5400W | 10000VA/ 9000W | |||
| INPUT | |||||
| Nominal voltage | 208/220/230/240Vac | ||||
| Input voltage range | 110~286Vac | ||||
| Frequency range | 40~70Hz (50/60Hz Auto-Sensing) | ||||
| Power factor | ≥0.99 | ||||
| Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) | |||||
| Bypass voltage range | 240V:+15% (Optional+10%) | ||||
| Min.voltage:-45% (Optional-20%,-30%) | |||||
| OUTPUT | |||||
| Output voltage | 208/220/230/240Vac | ||||
| Power factor | 0.9 | ||||
| Voltage regulation | ±1% | ||||
| Output frequency | Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) | |||
| Bat. Mode | (50/60±0.1%)Hz | ||||
| Crest factor | 3:01 | ||||
| Harmonic distortion (THDv) | ≤2% Linear load | ||||
| ≤5% Non linear load | |||||
| Transfer time | AC mode to Bat.Mode | 0ms | |||
| Inverter to Bypass | 0ms | ||||
| Output waveform | Pure Sinewave | ||||
| Overload | Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately | |||
| Bypass Mode | 40A (Breaker) | 63A (Breaker) | |||
| Efficiency | 94% | ||||
| BATTERY | |||||
| Battery voltage | ±96/±108/±120Vdc (Adjustable) | ±120Vdc | ±96/±108/±120Vdc (Adjustable) | ±120Vdc | |
| Capacity (Standard unit) | 9Ah/12V (7Ah/12V optional) | ||||
| Typical recharging time | 6~8 hours (to 90% of full capacity) | ||||
| Charging current | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) | ||||
| INDICATORS | |||||
| LED display | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault | ||||
| LCD display | Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, | ||||
| Battery voltage,Inner temperature& Remaining battery backup time | |||||
| ALARM | |||||
| Battery mode | Beeping every 4 seconds | ||||
| Battery low | Beeping every second | ||||
| Overload | Beeping twice every second | ||||
| Fault | Continously beeping | ||||
| PHYSICAL | |||||
| Dimension W x D×H (mm) | 440 x 625 x 86.5 | ||||
| Net weight (kg) | 16 | 18 | |||
| ENVIRONMENT | |||||
| Operating temperature | 0℃~40℃ | ||||
| Storage temperature | -25℃~55℃ | ||||
| Humidity range | 20~95%RH @ 0~40℃ (Non condensing) | ||||
| Altitude | <1500m,derating required when>1500m | ||||
| Noise level | <55db at 1 Meter | <58db at 1 Meter | |||
| STANDARDS | |||||
| Safety | IEC/EN62040-1,IEC/EN62477-1 | ||||
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
||||
- Output Capacity
- 9000W
- Battery
- External
Thank you for your interest in SYSTEMCO sarl.
Systemco Sarl has teamed up with best logistics to deliver your orders accurately, in good condition and always on time.
Once you place your order with us, your order will be processed by our employees and sent to your shipping address within 24 to 48 hours workday.
In order to track your package, you can contact our logistic team either by phone 0 1- 69 69 68 or by email ([email protected])